COVER INTERPOSER TRAY (B704)
SM 1-113 B132/B200
Installation
4. Attach the sponge strip [A] that is supplied with the finisher.
5. Attach the guide plate (removed from the finisher) to the cover interposer.
Attach the front end [B] of the plate ( x 1).
Attach the rear end of the plate with the anti-static brush [C] ( x 1).
Important: Use the two small tapping screws that are supplied, and not the
machine screws removed from the finisher guide plate.
6. Release the lock lever [D] ( x 1).
7. Attach the pad [E]. (This pad is provided with the finisher.)
8. Slowly push the finisher against the side of the
machine until the brackets [F] go into the slots.
WARNING!
Move the finisher carefully, or you will bend the
entrance guide plates.
9. Attach the lock lever [D] ( x 1).
10. Connect the connector [G] to the copier.
Important! Check the duct $ on the left side of the
machine. Make sure that the sponge does not prevent air
flow through this duct.