SPECIAL PROCEDURES
SM 4-7 B132/B200
Code Error Problem Recovery
ITB misaligned Reinstall ITB.
Image density too light, uneven. Output a coverage pattern with SP2109 002 Pattern
1. Check the images.
21-23
Auto density out of range (over
or lower)
Connector loose.
Connector dirty.
Harness defective.
Other
Check the ID sensor and its connection.
ITB misaligned Reinstall ITB.
SP2153 023 set to 1 (OFF). Set SP2153 023 to 0 (ON).
Large amount of K skew. Print a trim pattern with SP2109 002 Patten 10.
31-33
Amount of skew calculated in
the coverage pattern abnormal.
Image density too light, uneven. Output a coverage pattern with SP2109 002 Pattern
1. Check the images.
ITB misaligned.
Image density too light. Output a coverage pattern with SP2109 002 Pattern
1. Check the images.
41-43
Intersecting lines of the grid
pattern.
Dirty, abnormal images. Output Pattern 1, 18, or 20 with SP2109 002 and
check the images.
ITB misaligned Reinstall ITB.
SP2153 023 set to 1 (OFF). Set SP2153 023 to 0 (ON).
The settings of sensor lights 1, 2, 3 are different from
the default setting, which is 2050. (These settings are
done with SP2153 020~022.)
Dirty, abnormal images. Output Pattern 1, 18, or 20 with SP2109 002 and
check the images.
51-53
Connector loose.
Connector dirty.
Harness defective.
Other
Check the ID sensor and its connection.