SERVICE PROGRAM TABLES
SM 5-35 B132/B200
Service Tables
2109 Test Pattern Write Test Pattern
Some of these test patterns are used for copy image adjustments but most are used
primarily for design testing. These test patterns do not use the IPU.
001 Image Add
Select "1" to have the patterns selected with
SP2109 002 print overlapped on one another.
[0~1/1] 0:Off, 1:On
002 Select Pattern Allows you to select the pattern to print.
[0~21/1]
0 Off 14 Horizontal Cross-Stitch
1 1-Dot Line 15 Crop Marks
2 1-Dot Slant Cross-Stripe 16 Vertical Belt
3 2-Dot Horizontal Line 17 Checkered Flag
4 2-Dot Vertical Line 18 1-Dot 20 mm Grid
5 1-Dot Horizontal Line 19 1-Dot 20 mm Slant Grid
6 1-Dot Vertical Line 20 Horizontal Grayscale
7 1-Dot Independent 21 Horizontal Grayscale-White Stripes
8 2-Dot Independent 22 --- Not Used ---
9 4-Dot Independent 23 --- Not Used ---
10 Trim Area 24 --- Not Used ---
11 Belt Pattern 25 --- Not Used ---
12 100% Coverage 26 --- Not Used ---
13 Vertical Cross-Stitch 27 --- Not Used ---
004 Col Select:YCMK [0~255/1]
005 Density:K [0~63/1]
006 Density:M
007 Density:C
008 Density:Y
011 Gray Density 1 [0~63/1]
012 Gray Density 2
013 Gray Density 3
014 Gray Density 4
015 Gray Density 5
016 Gray Density 6
017 Gray Density 7
018 Gray Density 8
019 Gray Density 9
020 Gray Density 10
021 Gray Density 11
022 Gray Density 12
023 Gray Density 13
024 Gray Density 14
025 Gray Density 15