SERVICE PROGRAM TABLES
B132/B200 5-68 SM
2791 Sp1:FC:LL Special Paper 1: FC Low
2792 Sp1:FC:ML Special Paper 1: FC Medium Low
2973 Sp1:FC:MM Special Paper 1: FC Medium
These SPs set the paper size correction coefficient for the image to paper transfer
bias threshold values calculated based on the reading of the absolute humidity from
the temperature/humidity sensor and the thresholds set with SP2304.
SP2791 – Up to SP2304 001: Threshold 1
SP2792 – More than SP2304 001 Threshold 1, up to SP23204 002 Threshold 2.
SP2793 – More than SP2304 002 Threshold 2, up to SP2304 003 Threshold 3.
SP2794 – More than 2304 003 Threshold 3, up to SP2304 004 Threshold 4.
SP2795 – More than 2304 004 Threshold 4
These settings apply only to the image area printed on Special Paper 1 in full-color
mode.
2791 2792 2973
007 Side1:PTR [10~250/5%] [10~250/5%] [10~250/5%]
008 Side1:SepDC
009 Side1:SepAC
012 Side2:PTR
013 Side2:SepDC
014 Side2:SepAC
2794 Sp1:FC:MH Special Paper 1: FC Medium High
2795 Sp1:FC:HH Special Paper 1: FC High
2794 2795
017 Side1:PTR [10~250/5%] [10~250/5%]
018 Side1:SepDC [10~250/5%]
019 Side1:SepAC [10~250/5%] [10~250/5%]
027 Side2:PTR
028 Side2:SepDC
029 Side2:SepAC
2801 Sp2 K Bias Set Bias for Special Paper 2: K
These SPs set the standard values of the electrical charges that are applied to 1)
create bias for image transfer from drum to ITB, 2) create bias for image transfer
from ITB to paper (PTR), and 3) neutralize the charges on the both sides of the
paper to separate the paper from the ITB (SepDC, SepAC). These settings are
used when printing on Special Paper 2 in the black-and-white mode and are applied
only to the image area.
001 ITB
[0~500/0.1 µa]
007 Side1:PTR
[-100~0/1 µa]
008 Side1:SepDC
[0~100/0.1 µa]
009 Side1:SepAC [80~120/0.1 kV]
012 Side2:PTR
[-100~0/1 µa]
013 Side2:SepDC
[0~100/0.1 µa]
014 Side2:SepAC [80~120/0.1 kV]