Loading...
SERVICE PROGRAM TABLES
SM 5-95 B132/B200
Service Tables
3820 Manual ProCon Execute Process Control Manually
Use this SP to execute process control manually.
3820 001 does potential control only.
3820 002 does potential control and toner density adjustment.
Note:
You must do SP3820 to enable any values you change with SP3531 (Procon
Target).
Use SP3561 to display the resuls of SP3820 execution.
001 Normal ProCon
002 Exe Density Adj
[0~0/1]
3821 ProCon OK? Display Result of Process Control Execution
Use this SP to display the history of process control executions. These SP codes are
used to troubleshoot processing control. For more, see "4.2 Process Control
Troubleshooting" in Section "4. Troubleshooting".
[0~99999999/1]
001 History:Last 006 History:Last 6
002 History:Last 2 007 History:Last 7
003 History:Last 3 008 History:Last 8
004 History:Last 4 009 History:Last 9
005 History:Last 5 010 History:Last 10
3891 Set ProCon Send Set Up Sending Process Control Data to NRS Center
This feature is not presently used. (March 2005)
[0~1/1]
3900 RsetProConSP Reset All Process Control SP Codes