SERVICE PROGRAM TABLES
SM 5-105 B132/B200
Service Tables
4932 MainScan Dot Adj Main Scan Dot Position Adjustment
Corrects the left or right side alignment of the red or blue filter on the CCD. For
more, see the last section in Section "3. Replacement and Adjustment".
001 R:Left
002 R:Right
003 B:Left
004 B:Right
[0~9/1]
4954 Read/Restore Std Chart Standard: Read/Restore
Use this SP to calibrate the scanner gamma on each machine connected with the
Copier Connection Kit.
001 Read New Chart
Reads the "Standard Color Test Chart" to calibrate
the scanner gamma curve for two machines
connected with the Copier Connection Kit. Do this SP
with the test chart on each connected machine.
002 Recall Prev Chart
Restores the scanner gamma to the previous value
(not the factory setting).
004 Set Std Chart DFU
4991 Image Path SW Image Path Switch
Use this SP to use the 10-key pad to enter the number to determine the image path.
001 IPU 0~14/1]
0 DFID input RGB images (upper 8 bits)
1 Synchronous RGB images in DFID
2 Data with shading correction on
3 Data with shading correction off
4 Data before black offset correction
5 Data after black offset correction
6 Shading data
7 Test pattern data (grayscale)
8 RGB image after line interval correction
9 RGB image after dot correction and pre-gamma
10 RGB image after vertiial line correction
11 RGB image after scanner gamma correction
12 RTB image after filtering with MTF
13 RTB image after ADS
14 RGB image after color processing
4992 ProCon γ Unit Select Process Control Unit
This SP selects either the printer or IPU to reflect process control gamma.
Note: This machine is fixed at 0 (Printer) and the setting cannot be changed.
[0~2/1]