and
Adjustment
5. Bracket [D] ( x 1)
6. Pull the drum [E] towards the front
(the left side in the illustration) while releasing the
charge roller [F] using the release levers
[G], and then remove the drum .
Never touch the drum surface with bare hands.
Re-installation
1. Replace the drum and close the PCDU ( x 2).
2. Put the opening cap [A in the previous procedure] back in its original place.
3. After replacing the drum, do these SPs:
SP 2001: Charge Bias Setting – make sure that this is at the default setting
SP 3001-2: P Sensor Initial Setting (P sensor = ID Sensor)
SP 2805: Process Setting
SP 2810-1: Grayscale Setting