Exposure Glass Cleaner
1. Attach the exposure glass cleaner holder [1] to the left side of the machine.
2. Place the exposure glass cleaner [2] inside the holder.
The exposure glass cleaner is used to clean the ARDF exposure glass, the glass strip
to the left of the large exposure glass.
Settings Relevant to the Service Contract
Change the necessary settings for the following SP modes if the customer has made a service
contract.
Item SP No. Function Default
A3/11" x 17"
double
counting
SP5-104-001
(SSP)
Specifies whether the counter is
doubled for A3/11" x 17" paper.
When you have to change this
setting, contact your supervisor.
"No": Single
counting
Service Tel.
No. Setting
SP5-812-001
through 004
5812-002 programs the service
station fax number. The number is
printed on the counter list when
the meter charge mode is
selected. This lets the user fax the
counter data to the service
station.