Detailed Description of SP5-749
SM Appendix 3-287 D129/D130
Appendix:
Service
Program
Mode Tables
Result Code Cause Solutions
20 (PART FAILED)
Failed to import some settings. The reason for the failure is logged in
"NgCode". Check the code.
♦ Reason for the Error (Ng-Name)
2. INVALID VALUE
The specified value exceeds the allowable
range.
3. PERMISSION ERROR
The permission to edit the setting is missing.
4. NOT EXIST
The setting does not exist in the system.
5. INTERLOCK ERROR
The setting cannot be changed because of
the system status or interlocking with other
specified settings.
6. OTHER ERROR
The setting cannot be changed for some
other reason.
21 (INVALID FILE)
Failed to import the file because it is
in the wrong format in the external
medium.
Check whether the file format is correct. The
log is in the form of a CSV file
22 (INVALID KEY)
The encryption key is not valid. Use the correct encryption key.
When exporting device information from the control panel, the data can be saved only
on an SD card.
The file format for exports is CSV.
3.13.6 EXPORTING DEVICE INFORMATION
When exporting SP device information from the control panel, the data is saved on an SD card.
1. Insert an SD card into the media slot on the side of the control panel.
2. Enter SP mode.
3. Press SP5-749-001
4. Select target SP settings to be exported.
Rev. 11/15/2012