Main SP Tables-3
D129/D130 5-18 SM
5.5 MAIN SP TABLES-3
5.5.1 SP3-XXX: PROCESS
3001 P Sensor Setting
001*
Current [0 to 43 / 13 / 0.1 mA ]
Allows you to reset the PWM of the ID sensor LED to avoid a service call
error after clearing NVRAM or replacing the NVRAM.
The PWM data is stored by executing SP-3001-2.
002
Initialization -
Performs the ID sensor initial setting. ID sensor output for the bare drum
(VSG) is adjusted automatically to 4.0 ±0.2 V.
Press "Execute" to start. Perform this setting after replacing or cleaning the
ID sensor, replacing the drum, or clearing NVRAM.
3045* Toner End Setting DFU
001 ON/OFF [0 to 1 / 0 / 1] 0=Off, 1=On
3902* New PCU Detection (Not used)
001
ON/OFF Setting
[0 to 1 / 0 / 1]
0: On, 1: Off
Turns on or off the new unit detection for the transfer belt unit and fusing
unit.