and
Adjustment
4.6.4 CHARGE ROLLER AND CLEANING ROLLER
1. Drum ( p.4-38)
2. Push the charge roller holder [A] toward the front of the drum (
x 2) and remove the
spring [B].
3. Charge roller [C].
Disengage the charge roller on the right side to remove it. Try to avoid touching the
charge roller.
4. Cleaning roller [D]
Disengage the cleaning roller on the left to remove it.
5. After replacing the charge roller and cleaning roller, check the value of SP2001-001. If it is
not at the standard value (1500), set SP2001-001 to "1500".
If this is not done, the carrier will be attracted to the drum because the charge roller
voltage will be too high.