Copy Adjustments: Printing/Scanning
SM 4-117 D129/D130
Replacement
and
Adjustment
4.16.5 TOUCH SCREEN CALIBRATION
After clearing the memory, replacing the operation panel or NVRAM, or if the touch panel
detection function is not working correctly, follow this procedure to calibrate the touch screen.
Do not attempt to use items [2] to [7] on the Self-Diagnostic Menu. These items are for
design use only.
1. Press
, "1", "9", "9", "3", and then press 5 times to open the Self-Diagnostics
menu.
2. On the touch screen press "Touch Screen Adjust" (or press "1").
3. Use a pointed (not sharp!) tool to press the upper left mark
.
4. Press the lower right mark
after it appears.
5. Touch a few spots on the touch panel to confirm that the marker (+) appears exactly where
the screen is touched.
If the + mark does not appear where the screen is touched, press Cancel and repeat from
Step 2.
6. When you are finished, press [#] OK on the screen (or press
).
7. Touch [#] Exit on the screen to close the Self-Diagnostic menu and save the calibration
settings.
Rev. 12/27/2012