shooting
SC Tables: SC6xx
610 D
Mechanical counter error: BK
This SC is only for NA models.
The machine detects the mechanical counter error when SP5987-001 is set
to "1".
ï‚§ Disconnected mechanical counter
ï‚§ Defective mechanical counter
620 D ADF communication error
-01 -
Communication error between machine and ADF
Communication error between machine and ADF with ASAP is detected.
ï‚§ Disconnected cable
ï‚§ ARDF defective
ï‚§ IPU board defective
External noise
-02 -
Communication error between IPU and ADF
After the ARDF is detected, the break signal occurs or communication
timeout occurs.
ï‚§ Incorrect installation of ARDF
ï‚§ ARDF defective
ï‚§ IPU board defective
ï‚§ External noise
621 D
Communication timeout error between IOB and finisher or mailbox
A break (low) signal is received from the finisher or the mailbox.
ï‚§ Disconnected cable
ï‚§ Defective IOB
ï‚§ Defective main board in the peripherals