Main SP Tables-1
D129/D130 5-12 SM
007
Paper Interval Time [0 to 10 / 5 / 1 sec]
Adjusts the threshold for paper feeding. When the time between trailing
edge detection and leading edge detection is within the value of this setting,
the machine determines that the paper is still being fed.
008
Web Motor Setting: Web End [0 to 60 / 27 / 1 sec]
Adjusts the motor rotation time after the web end.
009
Web Motor Rotation: Power On [0 to 10 / 0 / 1 times]
Adjusts the number of web motor rotations at the re-load state.
010
Web Motor Interval: Pre-idle [0 to 30 / 0 / 1 sec]
Adjusts the motor waiting time after the fusing motor idling.
011
Web Motor Rotation: Pre-idle [0 to 10 / 0 / 1 times]
Adjusts the number of web motor rotations at the fusing idling state.
1950*
Tray Lock at Jam [0 or 1 / 0 / 1 ] 0= OFF, 1= ON