Main SP Tables-4
D129/D130 5-38 SM
4807
SBU Test Pattern Change
[0 to 255 / 0 / 1 /step]
1: Grid pattern
2: Gradation main scan
3: Gradation sub scan
4 to 250: Default (Scanning Image)
4808 Factory Setting Input
002* Execution Flag
4918
Man Gamma Adj (DFU)
Adjusts the offset data of the printer gamma for black in Photo mode or
Letter mode.
Touch [Change] to open the printer gamma screen.
Enter the manual gamma adjustment screen.
4954 Read/Restore Std
001
Read New Chart
Execute the scanning of the A4 chart.
002
Recall Prev Chart
Clear the data of the scanned A4 chart.
003
Read Std Chart
Execute the scanning of the A4 standard chart.
004
Set Std Chart
Overwrite the standard data.
005*
Read/Restore Std [0 to 255 / 0 / 1]
Adjusts chromaticity rank. When replacing the scanner lamp, select a
number according to the barcode on the new scanner lamp.