Tables
5404
User Code Count Clear
Clears the counts of the user codes assigned by the key operator to restrict
the use of the machine. Press [Execute] to clear.
5413 Lockout Setting
001
Lockout On/Off [0 to 1 / 0 / 1] 0: OFF, 1:ON
Turns on or off the account lock for the local address book account.
002
Lockout Threshold [1 to 10 / 5 / 1]
Sets the maximum trial times for accessing the address book account.
003
Cancellation On/Off
[0 to 1 / 0 / 1]
0: OFF (Lockout is not cancelled.)
1: ON (Lockout is cancelled if a user ID and
password are correctly entered after the lockout
function has been executed and a specific time has
passed.)
Turns on or off the cancellation function of the account lockout.
004
Cancellation Time [1 to 9999 / 60 / 1 min]
Sets the interval of the retry for accessing the local address book account
after the lockout function has been executed.
This setting is enabled only if SP5413-3 is set to "1" (ON).