Loading...
Main SP Tables-5
SM 5-55 D129/D130
Service
Tables
5515*
SC/Alarm Setting
With @Remote in use, these SP codes can be set to issue an SC call when
an SC error occurs. If this SP is switched off, the SC call is not issued when
an SC error occurs.
001 SC Call
[0 or 1 / 1 / 1]
0: OFF
1: ON
002 Service Parts Near End Call
003 Service Parts End Call
004 User Call
006 Communication Information Test Call
007 Machine Information Notice
008 Alarm Notice
010 Supply Automatic Ordering Call
011 Supply Management Report Call
012 Jam/Door Open Call
5516
Individual PM Part Alarm Call
With @Remote in use, these SP codes can be set to issue an PM alarm call
when one of the SP parts reaches its yield.
001
Disable/Enable Setting (0: Not
send, 1: Send)
[0 or 1 / 1 / - ]
0: Not send, 1: Send
004
Percent yield for triggering PM alert [1 to 255 / 75 / 1 %/step]

Table of Contents