Tables
209 Instl Clear
Releases the machine from its Embedded RCG
Gate setup.
NOTE: Turn off and on the main power switch after
this setting has been changed.
250 CommLog Print Prints the communication log.
5821* Remote Service Address
002 RCG IP Address
Sets the IP address of the RCG (Remote
Communication Gate) destination for call
processing at the remote service center.
[00000000h to FFFFFFFFh / 00000000h / 1]
003 RCG Port
Sets the port number of the RCG (Remote
Communication Gate) destination for call
processing at the remote service center.
[0 to 65535 / 443 / 1]
004 RCG URL Path
Sets the URL path of the RCG (Remote
Communication Gate) destination for call
processing at the remote service center.
[0 to 16 characters / /RCG/services/ /-]
5824
NV-RAM Data Upload
Uploads the NVRAM data to an SD card. Push Execute.
Note: When uploading data in this SP mode, the front door must be open.
5825
NV-RAM Data Download
Downloads data from an SD card to the NVRAM in the machine. After
downloading is completed, remove the card and turn the machine power off
and on.