Tables
5853
Stamp Data Download
Push [Execute] to download the fixed stamp data from the machine ROM
onto the hard disk. Then these stamps can be used by the system. If this is
not done, the user will not have access to the fixed stamps ("Confidential",
"Secret", etc.).
You must always execute this SP after replacing the HDD or after formatting
the HDD. Always switch the machine off and on after executing this SP.
5856 Remote ROM Update
002
When set to "1" allows reception of firmware data via the local port (IEEE
1284) during a remote ROM update. This setting is reset to zero after the
machine is cycled off and on. Allows the technician to upgrade the firmware
using a parallel cable
[0 to 1 / 0 / 1 step]
0: Not allowed
1: Allowed
5857 Save Debug Log
001
On/Off (1:ON 0:OFF)
Switches on the debug log feature. The debug log cannot be captured until
this feature is switched on.
[0 to 1 / 0 / 1]
0: OFF, 1: ON
002
Target (2: HDD 3: SD)
Selects the destination where the debugging information generated by the
event selected by SP5858 will be stored if an error is generated
[2 to 3 / 2 / 1]
2: HDD, 3: SD Card