Main SP Tables-7
D129/D130 5-126 SM
7804
PM Counter Reset
Resets the PM counter.
Touch [Execute] two times > "Completed" > [Exit]
001
Paper
Resets the PM counter of the paper.
002
PCD
Resets the PM counter of the PCD (Drum and Development unit except
developer).
003
Transfer
Resets the PM counter of the transfer unit.
004
Fuser
Resets the PM counter of the fuser unit.
005
Web
Reset the PM counter of the web unit.
006
All Clear
Resets all PM counter
7807
SC/Jam Counter Reset
Resets the SC and jam counters. To reset, press Execute on the touch
panel.