Tables
021
Day Threshold: PCD [1 to 30 / 15 / 1 days]
Adjusts the threshold day for the near end for the PCD.
022
Day Threshold: Transfer Unit [1 to 30 / 15 / 1 days]
Adjusts the threshold day for the near end for the transfer unit.
023
Day Threshold: Fusing Unit [1 to 30 / 15 / 1 days]
Adjusts the threshold day for the near end for the fusing unit.
7953 Operation Env Log
001
T<10 [0 to 99999999 / 0 / 1 mm]
Displays the PCU rotation distance in the environment: T<10°C
002
10<=T<=17 [0 to 99999999 / 0 / 1 mm]
Displays the PCU rotation distance in the environment: 10°C<=T<=17°C
003
17<T<23 [0 to 99999999 / 0 / 1 mm]
Displays the PCU rotation distance in the environment: 17<=T<=23
004
23<=T<=27 [0 to 99999999 / 0 / 1 mm]
Displays the PCU rotation distance of the environment: 23<=T<=27
005
27<=T<=32 [0 to 99999999 / 0 / 1 mm]
Displays the PCU rotation distance of the environment: 27<=T<=32
006
32<T [0 to 99999999 / 0 / 1 mm]
Displays the PCU rotation distance of the environment: 32<T
7954
Env Log Clear
Resets the environment logs (SP7953).