shooting
144 D
SBU connection error
The SBU connection cannot be detected at power on or recovery from the
energy save mode.
Defective SBU
Defective harness
Defective detection port on the BCU
161 D
IPU error
The error result of self-diagnostic by the ASIC on the IPU is detected.
Defective IPU
Defective connection between IPU and SBU
162 D
IPU PCIE Communication error
The link up interrupt did not proceed from the LYRA when the main switch
was turned on or when recovering from the energy saver mode.
Defective IPU
Defective BCU
165 D
Copy Data Security Unit error
The copy data security board is not detected when the copy data security
function is set "ON" with the initial setting.
A device check error occurs when the copy data security function is set to
"ON" with the initial setting.
Incorrect installation of the copy data security board
Defective copy data security board