shooting
324 D
Development paddle motor error
The machine detects a lock signal error from the development puddle motor
for 2 seconds after the drum motor has turned on.
Overload on the development puddle motor
Defective development puddle motor
Defective harness
Defective IOB
350 D
ID sensor pattern test error
One of the following readings occurred 10 times in the ID sensor output when
the ID sensor pattern was checked:
1) Vsp > 2.5V
2) Vsg < 2.5V
3) Vsp =0V
4) Vsg = 0V
ID sensor connector defective
Poor ID sensor connector connection
I/O board (IOB) defective
Poor writing of ID sensor pattern on the drum
High voltage supply board defective
351 D
ID sensor Vsg test error
When the ID sensor was checked, the ID sensor output voltage is 5.0V while
the LED current value is 0.
ID sensor defective or dirty
ID sensor connector defective
Poor ID sensor connection
I/O board (IOB) defective
Scanning system defective
High voltage supply board defective
Defect at the ID sensor pattern writing area of the drum