shooting
5.2.2 SC CODE DESCRIPTIONS
SC1xx: Scanning
No.
Definition
Symptom Possible Cause
101
-01
B
Exposure Lamp Error (D158/D159)
The standard white level was
not detected properly when
scanning the white plate.
Exposure lamp
Exposure lamp stabilizer
Exposure lamp connector
Dirty scanner mirror or scanner mirror
out of position
SBU board
SBU connector
Lens block out of position
101
-02
B
Exposure Lamp Error (LED light adjustment) (D158/D159)
LED error flag is on
Defective LED
Defective LED driver
Defective harness
101 B
Exposure Lamp Error (D160/D161/D170)
The standard white level was
not detected properly when
scanning the white plate.
Defective LED
Defective harness
Dirty scanner mirror or scanner mirror
out of position
102 B
LED light adjustment error (D158/D159)
Reading white plate level is
over prescribed rate.
Defective LED
Defective LED driver
Defective SBU
Defective BICU
Defective harness