Main SP Tables-5
SM Appendix 3-79 D158/D159/D160/D161/D170
Appendix:
Service
Program
Mode Tables
3.5 MAIN SP TABLES-5
3.5.1 SP5-XXX (MODE)
5001
[All Indicators On] (D160/D161/D170)
All LEDs turn on. The LCD turns on or off every 3 seconds. Press the reset key
to end this program.
001 - CTL -
5009
[Add Disp. Lang] (D158/159)
Adds language available in user choice. (Only the languages registered in the
machine)
Refer to the displayed language list to set in the way showed below.
List Num.Assigned Bit Switch
No.1~8BIT1 to 8 (SP5009-201)
No.9~16BIT1 to 8 (SP5009-202)
No.17~24BIT1 to 8 (SP5009-203)
No.25~32BIT1 to 8 (SP5009-204)
Example: To add American(No.3 in the list) or Czech (No.15)
Turn Bit 3 of “SP5009-201” 0 to 1 for American.
Turn Bit 7 of “SP5009-202” 0 to 1 for Czech .
After setting, turn the main power switch off and on to make the setting valid.
201 Bit SW *CTL
[1 to 255/ 0 / 1 / step]
202 Bit SW *CTL
203 Bit SW *CTL
204 Bit SW *CTL