Using SP Modes
D158/D159/D160/D161/D170 6-16 SM
6.4.3 MEMORY CLEAR
The basic machine (D170: the machine without the optional controller) stores all the data in the
NVRAM on the BICU. The data is cleared by SP5-801-002 (Memory Clear - Engine) (see
exceptions).
The GDI or GW+ machines (the machines with the optional controller) store the engine data in the
NVRAM on the BICU, and store the other data in the NVRAM on the optional controller. To
distinguish between the engine data and the other data, see SP5-801-003 through -024. This
service program (003-024) handles the controller data. Any data that is not handled by SP 5801 is
the engine data. The data in the BICU NVRAM (engine data) is cleared by SP5-801-002.
Machine Data NVRAM Cleared by Remarks
Basic
(D170)
All data BICU SP5-801-002
GW+
(D158/D159)
Engine data BICU SP5-801-002
Any data other than
controller data
Controller data GW + Controller
SP5-801-001
-003 to -025
SCS, IMH, MCS,
Copier application,
Printer application,
Scanner application,
Web service/network
application, NCS,
R-Fax, DCS, UCS
GDI
(D160/D161)
Engine data BICU SP5-801-002
Any data other than
controller data
Controller data GDI Controller
SP5-801-001
-003 to -025
Copier application,
Printer application,
Scanner application,
Web service/network
application