Tables
- Exceptions -
SP5-801-002 (Memory Clear - Engine) clears most of the settings and counters stored in the
NVRAM on the BICU (the values return to their default values). However, the following settings
are not cleared:
SP5-807-001 (Area Selection)
SP5-811-001 (Serial Num Input [Code Set])
SP5-811-003 (Serial Num Input [ID2 Code Display])
SP5-812-001 (Service TEL [Telephone])
SP5-812-002 (Service TEL [Facsimile])
SP5-907-001 (Plug & Play)
SP 7 (Data Log)
SP 8 (History)
SP5-801-002 (Memory Clear - Engine) after you have replaced the BICU NVRAM or when the
BICU NVRAM data is corrupted. When the program ends normally, the message "Completed"
shows. When you have replaced the controller NVRAM or when the controller NVRAM data is
corrupted, use SP5-801-001 (Memory Clear / All Clear)
- With SD Card (D158/D159 models only)-
1. Upload the NVRAM data to the SD card (
p.6-10 "NVRAM Data Upload/Download").
2. Print out all SMC data lists (
p.6-37).
Be sure to print out all the lists. You have to manually change the SP settings if the
NVRAM data upload ends abnormally.
3. Select SP5-801-002.
4. Press the OK key.
5. Select "Execute." The messages "Execute?" followed by "Cancel" and "Execute" shows.
6. Select "Execute."
7. When the program has ended normally, the message "Completed" shows. If the program has
ended abnormally, an error message shows.
8. Press the cancel key.
9. Turn the main switch off and on.
10. Download the NVRAM data from the SD card.