Tables
6.4.5 OUTPUT CHECK
- Conducting an Output Check –
To prevent mechanical or electrical damage, do not keep an electrical component on for a
long time.
1. Select SP5-804.
2. Select the number (see the table below) corresponding to the component.
3. Select "ON."
4. To stop the operation, select "OFF."
- Output Check Table -
Number 005, 006, 040, and 041 may not respond when the fusing temperature is high.
Num. Component (D160/D161/D170)
001 Main Motor Forward
002 Main Motor Reverse
003 Quenching Lamp
004 Toner Supply Motor Forward
005 Fan Motor High
006 Fan Motor Low
007 Registration Clutch
008 By-pass Feed Clutch
009 Upper Feed Clutch
010 Lower Feed Clutch
011 BK-Low Lift Motor Up
012 BK-Low Lift Motor Down
013 Relay Clutch
014 BK-Relay Clutch
015 BK-Upper Feed Clutch