Service Call Conditions
D158/D159/D160/D161/D170 5-14 SM
No.
Definition
Symptom Possible Cause
354 B
ID sensor : Auto adjustment time-out (In-process) (D158/D159)
When the ID sensor is
adjusting Vsg automatically.
Defective ID sensor
Disconnection of the harness to the
ID sensor
Bad electrical contact of the ID
sensor connector
Defective BCU
Defective laser unit
Defective developer density
Defective high-voltage power pack
Dirty ID sensor
355 D
P sensor error (D158/D159)
SC350~354 happen during
normal operation. This error
isn't displayed on the panel
but is left in the error log.
Defective ID sensor
Disconnection of the harness to the
ID sensor
Bad electrical contact of the ID
sensor connector
Defective BCU
Defective laser unit
Defective developer density
Defective high-voltage power pack
Dirty ID sensor
389 D
TD sensor error (D158/D159)
Detected the following value
TD sensor output value <
0.2V
TD sensor output value >
4.0V
10 times in series.
Defective TD sensor
Bad contact of the connector to the
TD sensor

Table of Contents