shooting
No.
Definition
Symptom Possible Cause
542 A
Fusing reload failed (center) (D160/D161/D170)
NOT reaching the reload
temperature in 20 ms after
starting fusing lamp control.
Defective thermistor
Disconnected fusing lamp
543 A
Fusing overheat error (center)
The fusing temperature is
over 230°C for 1 second
(detected by the thermistor).
Fusing thermistor
Power supply board
544 A
Fusing overheat error (center) 2
The fusing temperature is
over 250°C for more than a
certain time (zero cross
signal x 3). (detected by the
fusing temperature monitor
circuit).
Fusing thermistor
Power supply board
545 A
Fusing lamp overheat error (center)
After the fusing temperature
reaches the target
temperature, the fusing
lamp does not turn off for 29
consecutive seconds.