EasyManua.ls Logo

Ricoh D158 - Page 293

Ricoh D158
976 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Service Call Conditions
D158/D159/D160/D161/D170 5-29 SM
Trouble-
shooting
No.
Definition
Symptom Possible Cause
SC672-10 D Controller start up error
After the machine was powered on, communication between the
controller and the operation panel was not established.
Controller stalled
Board installed incorrectly
Controller board defective
Operation panel connector loose, broken, or defective
Controller late
Turn the main power off/on.
Check the connection of the controller board.
Replace the controller board.
Check the control panel harness.
SC672-11 D Controller start up error
After the machine was powered on, communication between the
controller and the operation panel was not established, or
communication with controller was interrupted after a normal
startup.
Controller stalled
Board installed incorrectly
Controller board defective
Operation panel connector loose, broken, or defective
Controller late
Turn the main power off/on.
Check the connection of the controller board.
Replace the controller board.
Check the control panel harness.
Rev. 11/07/2013

Table of Contents

Related product manuals