Service Call Conditions
D158/D159/D160/D161/D170 5-31 SM
Trouble-
shooting
No.
Definition
Symptom Possible Cause
SC672-99 D Controller start up error
The operation panel software ended abnormally.
Controller stalled
Board installed incorrectly
Controller board defective
Operation panel connector loose, broken, or defective
Controller late
Turn the main power off/on.
Check the connection of the controller board.
Replace the controller board.
Check the control panel harness.
681
-01
B Device ID is not identified. (D158/D159)
-06 B Channel error (D158/D159)
-11 B Device error (No ID chip) (D158/D159)
-16 B Communication failed (D158/D159)
-21 B Timeout error (D158/D159)
-26 B Device detection suspended (D158/D159)
-31 B The requested buffer is full (D158/D159)
-36 B No error code (D158/D159)
Retry of ID tag
communication fails three
times after the machine
has detected the ID tag
error.
Caused by noise
⇒
Rev. 11/07/2013