Service Call Conditions
D158/D159/D160/D161/D170 5-70 SM
SC No. Level Error Name/Error Condition/Major Cause/Solution
SC864-07 D
HDD data CRC error
During HDD operation, the HDD returned a CRC error.
Bad sectors were generated during operation.
(An error occurred in partition "f".)
Format the HDD.
Replace the HDD.
SC No. Level Error Name/Error Condition/Major Cause/Solution
SC864-08 D
HDD data CRC error
During HDD operation, the HDD returned a CRC error.
Bad sectors were generated during operation.
(An error occurred in partition "g".)
Format the HDD.
Replace the HDD.
SC No. Level Error Name/Error Condition/Major Cause/Solution
SC864-09 D
HDD data CRC error
During HDD operation, the HDD returned a CRC error.
Bad sectors were generated during operation.
(An error occurred in partition "h".)
Format the HDD.
Replace the HDD.
Rev. 01/16/2014