Main SP Tables-2
D158/D159/D160/D161/D170 3-22 SM Appendix
2201
[Development Bias Adjust] (D158/D159)
[Dv Bias Adj] (D160/D161/D170)
-
001
Printing *ENG
[-1500 to 0 / -550 / 10 V / step]
Adjusts the voltage applied to the development roller for printing. Image density
becomes higher when you specify a smaller value (a greater absolute value).
Image density becomes lower when you specify a greater value (a smaller
absolute value).
02
P Pattern Revision
(ID Sensor Pattern)
*ENG
[0 to 4 / 0 / 1 / step]
0: Normal
1: Drak
2: Light
3: Darker
4: Lighter
Adjusts the voltage applied to the development roller for the ID sensor pattern.
The voltage applied is obtained by adding SP2-201-002 to SP2-201-001. The
setting affects ID sensor pattern density, which in turn affects the toner supply.
003
ID Sensor Pattern
(Temporally Input)
(ID Pattern Voltage)
*ENG
[-700 to -300 / -350 / 10 V / step]
Adjusts the voltage applied to the development roller when generating the ID
sensor pattern. The actual voltage applied is this setting plus the value of
SP2-201-001. The setting affects ID sensor pattern density, which in turn
affects the toner supply.