Main SP Tables-4
SM Appendix 3-43 D158/D159/D160/D161/D170
Service
Program
Mode Tables
4305
[APS Priority] (D160/D161/D170)
0: Normal Detection
1: LT SEF LEF - A4 SEF LEF(US)
A4 SEF LEF - LT SEF LEF(Except US/CHN)
A3 SEF,B4 SEF – 8K SEF(CHN)
A4 SEF,B5 SEF – 16K SEF(CHN)
A4 LEF,B5 LEF – 16K LEF(CHN)
001
- *ENG
[0 to 1 / 0 / 1 / step]
4308
[Scan Size Detection] (D158/D159)
Selects whether the machine detects the scan size.
0:OFF
1:ON
2:APS
001
Detection ON/OFF *ENG
[0 to 2 / 1 / 1 / step]
4309 [Scan Size Detect:Setting] (D158/D159)
001
Original Density Thresh *ENG
[0 to 255 / 18 / 1 digit / step]
Adjusts the density for the scan size detection.
002
Detection Time *ENG
[20 to 100 / 60 / 20 msec / step]
Adjusts the detection time for scan size detection.
003
Lamp ON:Delay Time *ENG
[40 to 200 / 40 / 10 msec / step]
Adjusts the timing when to lamp on for the scan size detection.
004
LED PWM Duty *ENG
[0 to 100 / 60 / 1 / step]
Adjusts the light value for the scan size detection.