Main SP Tables-5
D158/D159/D160/D161/D170 3-104 SM Appendix
5413 [Lockout Setting] (D158/159)
001
Lockout On/Off *CTL
[0 or 1 / 0 / 1/step]
0: OFF, 1: ON
Switches on/off the lock on the local address book account.
002
Lockout Threshold *CTL
[1 to 10 / 5 / 1time/step]
Sets a limit on the frequency of lockouts for account lockouts.
003
Cancellation On/Off *CTL
[0 or 1 / 0 / 1/step]
0: OFF (lockout not cancelled)
1: ON (system waits, cancels lockout
if correct user ID and password are
entered)
Determines whether the system waits the prescribed time for input of a correct
user ID and password after an account lockout has occurred.
004
Cancellation Time *CTL
[1 to 9999 / 60 / 1min./step]
Determines the length of time that the system waits
for correct input of the user ID and password after a lo
ckout has occurred. This
setting is used only if
SP5413-3 is set to "1" (on).
5414 [Access Mitigation] (D158/159)
001
Mitigation On/Off *CTL
[0 or 1 / 0 / 1/step]
0: OFF, 1: ON
Switches on/off masking of continuously used IDs and passwords that are
identical.
002
Mitigation Time *CTL
[0 to 60 / 15 / 1min./step]
Sets the length of time for excluding continuous access for identical user IDs
and passwords.

Table of Contents