[Stamp Positon Adj.] (D158/159)
Adjusts the stamp position.
001 - *ENG
[-5.0 to 5.0 / 0.0 / 0.1 mm / step]
6016
[Original Size Detect Setting] (D158/159)
[ADF Size Detect] (D160/D161/D170)
Specifies the original size for a size detected by the original sensor, since
original sensors cannot recognize all sizes.
001 - *ENG
[0 to 255 / 0 / 1 / step]
6017
[DF Magnification Adj.] (D158/159)
-
001 - *ENG
[-5.0 to 5.0 / 0.0 / 0.1 % / step]
6020
[Skew Correction Moving Setting] (D158/159)
Sets whether or not to skew correction operation.
001 - *ENG
[0 or 1 / 0 / 1 / step]
6154 [INPUT Check] (D158/159)
001 1 bin:Set Detection ENG
[0 or 1 / 0 / 1 / step]
003 1BIN: Paper Remain ENG
[0 or 1 / 0 / 1 / step]
004 1BIN: Cover Open ENG
[0 or 1 / 0 / 1 / step]
6155 [OUTPUT Check] (D158/159)
002
1BIN SOL ENG
[0 or 1 / 1 / 1 / step]
Drives the 1 bin solenoid to check the operation. Turns off automatically in 10
seconds after turned on.