EasyManua.ls Logo

Ricoh D158 - Page 651

Ricoh D158
976 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Main SP Tables-6
SM Appendix 3-193 D158/D159/D160/D161/D170
Appendix:
Service
Program
Mode Tables
6010
[Stamp Positon Adj.] (D158/159)
Adjusts the stamp position.
001 - *ENG
[-5.0 to 5.0 / 0.0 / 0.1 mm / step]
6016
[Original Size Detect Setting] (D158/159)
[ADF Size Detect] (D160/D161/D170)
Specifies the original size for a size detected by the original sensor, since
original sensors cannot recognize all sizes.
001 - *ENG
[0 to 255 / 0 / 1 / step]
6017
[DF Magnification Adj.] (D158/159)
-
001 - *ENG
[-5.0 to 5.0 / 0.0 / 0.1 % / step]
6020
[Skew Correction Moving Setting] (D158/159)
Sets whether or not to skew correction operation.
001 - *ENG
[0 or 1 / 0 / 1 / step]
6154 [INPUT Check] (D158/159)
001 1 bin:Set Detection ENG
[0 or 1 / 0 / 1 / step]
003 1BIN: Paper Remain ENG
[0 or 1 / 0 / 1 / step]
004 1BIN: Cover Open ENG
[0 or 1 / 0 / 1 / step]
6155 [OUTPUT Check] (D158/159)
002
1BIN SOL ENG
[0 or 1 / 1 / 1 / step]
Drives the 1 bin solenoid to check the operation. Turns off automatically in 10
seconds after turned on.