Main SP Tables-7
SM Appendix 3-205 D158/D159/D160/D161/D170
Service
Program
Mode Tables
006 Distance60k *ENG
[0 to 255/ - / 1 /step]
007 Distance120k *ENG
7804
[Reset-PM Count]
Clears the PM counter.
Press the Enter key after the machine asks “Execute?”, which will store the PM
counter value in SP7-906 (PM Counter - Previous) and reset the value of the
current PM counter (SP7-803) to “0”.
001 Paper CTL
[- / - / -]
[Execute]
002 60k part ENG Clears the unit counter for each unit.
[- / - / -]
[Execute]
003 120k part ENG
7807
[Reset-SC/Jam]
Resets the SC, paper, original, and total jam counters. When the program ends
normally, the message "Completed" is displayed.
SP7-807-1 does not reset the following logs: SP7-507 (Display-Paper
Jam History) and SP7-508 (Display-Original Jam History).
001 Reset-SC/Jam CTL
[- / - / -]
[Execute]