Service
Program
Mode Tables
7991
[Dsply-Info Count] (D160/D161/D170)
Displays the total operating time or the total number of operations. The time is
displayed in the following format: day: hour: minute: second.
001 Dsply-Timer Count ENG
Displays the total time while machine
is on.
002 Dsply-APS Working ENG
Displays the total time while APS is
working.
[0 to 9999999 / - / 1 min / step]
003 Dsply-ID S Work ENG
Displays the ID sensor operating
time.
[0 to 9999999 / - / 1 sec / step]
004 Dsply-Dev Counter ENG
Developer counter.
[0 to 9999999/ - / 1 mm / step]
005 Dsply-ID Er Count ENG
ID sensor error detected counter.
[0 to 255 / - / 1 / step]
7992 [Reset-Info Count] (D160/D161/D170)
001 Reset-Timer Count ENG
Resets the total time (SP7-991-001)
[- / - / -]
[Execute]
005 Reset-ID Er Count ENG
Resets ID sensor error detected
counter. (SP7-991-005)
[- / - / -]
[Execute]