Input and Output Check
D158/D159/D160/D161/D170 3-262 SM Appendix
6008
[ADF OUTPUT Check] (D158/159)
-
003
Feed Motor Forward ENG
[0 or 1 / 0 / 1 / step]
0:Off
1:On
Rotats the paper feed motor to check the operation of ADF.
004
Feed Motor Reverse ENG
[0 or 1 / 0 / 1 / step]
0:Off
1:On
Reverses the paper feed motor to check the operation of the load on the ADF.
005
Relay Motor Forward ENG
[0 or 1 / 0 / 1 / step]
0:Off
1:On
Rotates the relay motor to check the operation of ADF.
006
Relay Motor Reverse ENG
[0 or 1 / 0 / 1 / step]
0:Off
1:On
Reverse the relay motor to check the operation of ADF.
011
Inverter Solenoid ENG
[0 or 1 / 0 / 1 / step]
0:Off
1:On
Drives the inverter Solenoid to check the operation of ADF.
012
Stamp ENG
[0 or 1 / 0 / 1 / step]
0:Off
1:On
Drives the stamp to check the operation of ADF.