Bit Switches - 1
D702 60 SM
System Switch 02 (SP No. 1-101-003)
No Function Comments
2
Forced reset after transmission
stalls
0: Off
1: On
With this setting on, the machine resets itself
automatically if a transmission stalls and fails
to complete the job.
4
File retention time
0: Depends on User Parameter
24 [18(H)]
1: No limit
1: A file that had a communication error will not
be erased unless the communication is
successful.
6-7
Memory read/write by RDS (0,0): All RDS systems are always locked out.
(0,1), (1,0): Normally, RDS systems are locked
out, but the user can temporarily switch RDS
on to allow RDS operations to take place. RDS
will automatically be locked out again after a
certain time, which is stored in System Switch
03. Note that if an RDS operation takes place,
RDS will not switch off until this time limit has
expired.
(1,1): At any time, an RDS system can access
the machine.
Bit 7 Bit 6 Setting
0 0 Always disabled
0 1 User selectable
1 0 User selectable
1 1 Always enabled
System Switch 03 (SP No. 1-101-004)
No Function Comments
0
to
7
Length of time that RDS is
temporarily switched on when
bits 6 and 7 of System Switch
02 are set to "User selectable"
00 - 99 hours (BCD).
This setting is only valid if bits 6 and 7 of
System Switch 02 are set to "User selectable".
The default setting is 24 hours.