NCU Parameters
D702 112 SM
Address Function Unit Remarks
68053C
International dial tone permissible
drop time
68053D
International dial wait interval
(LOW)
-
68053E
International dial wait interval
(HIGH)
68053F
Country dial tone upper frequency
limit (HIGH)
Hz (BCD)
If both addresses
contain FF(H), tone
detection is disabled. 680540
Country dial tone upper frequency
limit (LOW)
680541
Country dial tone lower frequency
limit (HIGH)
If both addresses
contain FF(H), tone
detection is disabled. 680542
Country dial tone lower frequency
limit (LOW)
680543 Country dial tone detection time
20 ms
If 680543 contains FF,
the machine pauses for
the pause time (680548
/ 680549).
680544
Country dial tone reset time
(LOW)
680545
Country dial tone reset time
(HIGH)
680546
Country dial tone continuous tone
time
- -
680547
Country dial tone permissible
drop time
20 ms -
680548 Country dial wait interval (LOW)
680549 Country dial wait interval (HIGH)
68054A
Time between opening or closing
the DO relay and opening the
OHDI relay
1 ms
See Notes 3, 6 and 8.
SP2-103-012
(parameter 11).
68054B Break time for pulse dialing 1 ms
See Note 3.
SP2-103-013
(parameter 12).
68054C Make time for pulse dialing 1 ms
See Note 3.
SP2-103-014
(parameter 13).