2 Command System RIGOL
MSO2000A/DS2000A Programming Guide
2-99
:FUNCtion:WREPlay:INTerval
Syntax
:FUNCtion:WREPlay:INTerval <interval>
:FUNCtion:WREPlay:INTerval?
Description
Set or query the time interval in waveform playback and the unit is s.
Parameter
Name Type Range Default
<interval> Real 100ns to 10s 100ns
Return Format
The query returns the time interval set in scientific notation.
:FUNCtion:WREPlay:FSTart
Syntax
:FUNCtion:WREPlay:FSTart <frame>
:FUNCtion:WREPlay:FSTart?
Description
Set or query the start frame of waveform playback.
Parameter
Name Type Range Default
<frame> Integer
1 to the maximum number of
frames recorded
1
Return Format
The query returns an integer.