RIGOL 2 Command System
2-166 MSO2000A/DS2000A Programming Guide
:MEASure:PERiod
Syntax 1
:MEASure:PERiod <chan>
Description 1
Enable the period measurement function of the specified channel.
Syntax 2
:MEASure:PERiod? <chan>
Description 2
Enable the period measurement function of the specified channel and return the measurement result.
Parameter
Name Type Range Default
<chan> Discrete
{D0|D1|D2|D3|D4|D5|D6|D7|D8|D9|D10|D11|
D12|D13|D14|D15|CHANnel1|CHANnel2|MATH}
--
Return Format
The query returns the measurement result in scientific notation.
Example
:MEASure:PERiod CHANnel1
:MEASure:PERiod? CHANnel1
You can use the following commands to query the statistic maximum, minimum, current value, average
and standard deviation of the period measurement values of the specified channel waveform. Sending the
following commands will enable the statistic function automatically.
:MEASure:PERiod:SMAXimum?
:MEASure:PERiod:SMINimum?
:MEASure:PERiod:SCURrent?
:MEASure:PERiod:SAVerage?
:MEASure:PERiod:SDEViation?