2 Command System RIGOL
MSO2000A/DS2000A Programming Guide
2-15
:BUS<n> Commands
:BUS<n>:MODE
:BUS<n>:DISPlay
:BUS<n>:FORMat
:BUS<n>:EVENt
:BUS<n>:EEXPort
:BUS<n>:DATA?
:BUS<n>:PARallel
:BUS<n>:RS232 (Option)
:BUS<n>:IIC (Option)
:BUS<n>:SPI (Option)
:BUS<n>:MODE
Syntax
:BUS<n>:MODE <mode>
:BUS<n>:MODE?
Description
Set or query the decoding mode of the specified bus.
Parameter
Name Type Range Default
<n> Discrete {1|2} --
<mode> Discrete {PARallel|RS232|IIC|SPI|CAN} PARallel
Explanation
RS232 decoding, I2C decoding, SPI decoding and CAN decoding are options and this command is only
valid when the corresponding options are installed.
Return Format
The query returns PAR, RS232, IIC, SPI or CAN.