EasyManuals Logo

Rigol MSO2000A Series Programming Guide

Rigol MSO2000A Series
376 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #347 background imageLoading...
Page #347 background image
2 Command System RIGOL
MSO2000A/DS2000A Programming Guide
2-331
:WAVeform:MODE
Syntax
:WAVeform:MODE <mode>
:WAVeform:MODE?
Description
Set or query the data reading mode of the
:WAVeform:DATA? Command.
Parameter
Name Type Range Default
<mode> Discrete {NORMal|MAXimum|RAW} NORMal
Explanation
NORMal: read the waveform data currently displayed on the screen.
MAXimum: in the run state, read the waveform data displayed on the screen; in the stop state, read
the waveform data in the internal memory.
RAW: read the waveform data in the internal memory.
Note: The waveform data in the internal memory can only be read when the oscilloscope is in the
stop state and please do not operate the oscilloscope during the reading process.
Return Format
The query returns NORM, MAX or RAW.

Table of Contents

Other manuals for Rigol MSO2000A Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rigol MSO2000A Series and is the answer not in the manual?

Rigol MSO2000A Series Specifications

General IconGeneral
BrandRigol
ModelMSO2000A Series
CategoryTest Equipment
LanguageEnglish

Related product manuals