2 Command System RIGOL
MSO2000A/DS2000A Programming Guide
2-241
:SYSTem:BEEPer
Syntax
:SYSTem:BEEPer <bool>
:SYSTem:BEEPer?
Description
Enable or disable the beeper; or query the status of the beeper.
Parameter
Name Type Range Default
<bool> Bool {{0|OFF}|{1|ON}} 0|OFF
Return Format
The query returns 0 or 1.
:SYSTem:DATE
Syntax
:SYSTem:DATE <year>,<month>,<day>
:SYSTem:DATE?
Description
Set or query the system date.
Parameter
Name Type Range Default
<year> Integer 2011 to 2099 --
<month> Integer 1 to 12 --
<day> Integer 1 to 31 (28, 29 or 30) --
Return Format
The query returns the current date in string. The year, month and date parameters are separated by
commas.