EasyManuals Logo
Home>Rigol>Test Equipment>MSO2000A Series

Rigol MSO2000A Series Programming Guide

Rigol MSO2000A Series
376 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #144 background imageLoading...
Page #144 background image
RIGOL 2 Command System
2-128 MSO2000A/DS2000A Programming Guide
:MASK:SOURce
Syntax
:MASK:SOURce <source>
:MASK:SOURce?
Description
Set or query the measurement source of the pass/fail test.
Parameter
Name Type Range Default
<source> Discrete {CHANnel1|CHANnel2} CHANnel1
Explanation
Only the channel enabled can be selected as the measurement source of the pass/fail test.
Return Format
The query returns CHAN1 or CHAN2.
:MASK:OPERate
Syntax
:MASK:OPERate <oper>
:MASK:OPERate?
Description
Run or stop the pass/fail test; or query the current status of the pass/fail test.
Parameter
Name Type Range Default
<oper> Discrete {RUN|STOP} STOP
Explanation
Before executing this command, use the
:MASK:ENABle command to enable the pass/fail test.
Return Format
The query returns RUN or STOP.