2 Command System RIGOL
MSO2000A/DS2000A Programming Guide
2-67
:CHANnel<n>:COUPling
Syntax
:CHANnel<n>:COUPling <coupling>
:CHANnel<n>:COUPling?
Description
Set or query the coupling mode of the specified analog channel.
Parameter
Name Type Range Default
<n> Discrete {1|2} --
<coupling> Discrete {AC|DC|GND} DC
Explanation
AC: the DC components of the signal under test are blocked.
DC: the DC and AC components of the signal under test can both pass the channel.
GND: the DC and AC components of the signal under test are both blocked.
Return Format
The query returns AC, DC or GND.
:CHANnel<n>:DISPlay
Syntax
:CHANnel<n>:DISPlay <bool>
:CHANnel<n>:DISPlay?
Description
Enable or disable the specified analog channel; or query the current status of the specified analog
channel.
Parameter
Name Type Range Default
<n> Discrete {1|2} --
<bool> Bool {{0|OFF}|{1|ON}} 0|OFF
Return Format
The query returns 0 or 1.