EasyManuals Logo
Home>Rigol>Test Equipment>MSO2000A Series

Rigol MSO2000A Series Programming Guide

Rigol MSO2000A Series
376 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #249 background imageLoading...
Page #249 background image
2 Command System RIGOL
MSO2000A/DS2000A Programming Guide
2-233
[:SOURce<n>]:MOD:AM:INTernal:FREQuency
Syntax
[:SOURce<n>]:MOD:AM:INTernal:FREQuency {<frequency>|MINimum|MAXimum}
[:SOURce<n>]:MOD:AM:INTernal:FREQuency? [MINimum|MAXimum]
Description
Set or query the modulating waveform frequency of AM. The default unit is Hz.
Parameter
Name Type Range Default
<frequency> Real 1Hz to 50kHz 1kHz
<n> Discrete {1|2} 1
Return Format
The query returns the current modulating waveform frequency in scientific notation.
[:SOURce<n>]:MOD:AM:INTernal:FUNCtion
Syntax
[:SOURce<n>]:MOD:AM:INTernal:FUNCtion <wave>
[:SOURce<n>]:MOD:AM:INTernal:FUNCtion?
Description
Set or query the modulating waveform of AM.
Parameter
Name Type Range Default
<wave> Discrete {SINusoid|SQUare|RAMP|NOISe} SINusoid
<n> Discrete {1|2} 1
Return Format
The query returns SIN, SQU, RAMP or NOIS.

Table of Contents

Other manuals for Rigol MSO2000A Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rigol MSO2000A Series and is the answer not in the manual?

Rigol MSO2000A Series Specifications

General IconGeneral
BrandRigol
ModelMSO2000A Series
CategoryTest Equipment
LanguageEnglish

Related product manuals